Just had this sent to me..hope it helps...
PSP
In order to comply with the new 2008 PSP rule regarding gun firing
modes, we recommend that Eclipse markers should be configured as follows -
Ego 7 / Ego 8
1. Enter the Setup menu
2. Select (PRESET) (LOAD) and choose the PSP option
3. Select (MAX ROF) and set the value to 13.0*
4. Select (OFF ROF) and set the value to 13.0* or less (recommend 12.0)
5. Select (PRESET) (SAVE) and choose the USER 1 option to save these
settings for future use.
6. Exit the Setup menu
7. Check the rate of fire on a league approved ROF meter.
Ego 5 / Ego 6
1. Enter the Setup menu
2. Select (MODE) and choose the RAMP 1 or PSP option
3. Select (ROF CAP) and set the value to 13.0*
4. Select (OFF ROF) and set the value to 13.0* or less (recommend 12.0)
5. Exit the Setup menu
6. Check the rate of fire on a league approved ROF meter.
Etek / Etek 2
1. Enter the Setup menu
2. Select Firing Mode (red) and set the value to 03.0 (Ramp 1)
3. Select Maximum ROF (green) and set the value to 13.0*
4. Select Maximum ROF with BBSS Disabled (blue) and set the value to
13.0 or less (recommend 12.0)
5. Exit the Setup menu
6. Check the rate of fire on a league approved ROF meter.
Planet Eclipse no longer provides software updates for the eBlade
platform, however the following may prove useful in setting these products
up to be compliant
E2 / Zero B
1. Fit fresh batteries to the loader that will be used and set the
loader speed as required
2. Enter the Setup menu
3. Select (MODE) and choose the RAMP 1 or PSP option
4. Set the COFF parameter to 40ms
5. Enable the breech sensor
6. Shoot the gun so that it ramps and measure the ROF on a rate of fire
meter
7. Adjust the COFF parameter and repeat 6 until the ROF is 13.0bps*
(increasing COFF reduces ROF)
8. Check that CDELAY + CON + COFF is greater than 77ms and if not then
increase CON
9. Exit the Setup menu
10. Check the rate of fire on a league approved ROF meter.
E1 (eBlade)
1. Fit fresh batteries to the loader that will be used and set the
loader speed as required
2. Enter the Setup menu
3. Set the COFF parameter to 40ms
4. Enable the breech sensor
5. Shoot the gun as quickly as you can and measure the ROF on a rate of
fire meter
6. Adjust the COFF parameter and repeat 5 until the ROF is 13.0bps*
(increasing COFF reduces ROF)
7. Check that CDELAY + CON + COFF is greater than 77ms and if not then
increase CON
8. Exit the Setup menu
9. Check the rate of fire on a league approved ROF meter.
*The rate of fire settings on Egos are accurate however not all rate of
fire meters will read the same. We recommend that guns be set on the
safe side of the legal limit. The difference between 13.0 and 13.33bps
is only 1 extra ball every 39 shots!
Millinnium
In order to comply with the new Millennium rule regarding gun firing
modes, Eclipse markers should be configured as follows -
Ego 7 / Ego 8
1. Enter the Setup menu
2. Select (PRESET) (LOAD) and choose the MILLEN option
3. Select (MAX ROF) and set the value to 11.8*
4. Select (OFF ROF) and set the value to 11.8*
5. Select (RAMP SET) (KICK IN) and set the value to 6.0
6. Select (RAMP SET) (SUSTAIN) and set the value to 6.0
7. Select (PRESET) (SAVE) and choose the USER 1 option to save these
settings for future use.
8. Exit the Setup menu
9. Check the rate of fire on a league approved ROF meter.
Ego 5 / Ego 6
1. Enter the Setup menu
2. Select (MODE) and choose the RAMP 3** option
3. Select (ROF CAP) and set the value to 11.8*
4. Select (OFF ROF) and set the value to 11.8*
5. Exit the Setup menu
6. Check the rate of fire on a league approved ROF meter.
Etek / Etek 2
1. Enter the Setup menu
2. Select Firing Mode (red) and set the value to 05.0 (Ramp 3)
3. Select Maximum ROF (green) and set the value to 11.8*
4. Select Maximum ROF with BBSS Disabled (blue) and set the value to
11.8*
5. Exit the Setup menu
6. Check the rate of fire on a league approved ROF meter.
Planet Eclipse no longer provides software updates for the eBlade
platform, however the following may prove useful in setting these products
up to be compliant
E2 / Zero B
1. Fit fresh batteries to the loader that will be used and set the
loader speed as required
2. Enter the Setup menu
3. Select (MODE) and choose the RAMP 3** option
4. Set the COFF parameter to 40ms
5. Enable the breech sensor
6. Shoot the gun so that it ramps and measure the ROF on a rate of fire
meter
7. Adjust the COFF parameter and repeat 6 until the ROF is 11.8bps*
(increasing COFF reduces ROF)
8. Check that CDELAY + CON + COFF is greater than 84ms and if not then
increase CON
9. Exit the Setup menu
10. Check the rate of fire on a league approved ROF meter.
E1 (eBlade)
1. Fit fresh batteries to the loader that will be used and set the
loader speed as required
2. Enter the Setup menu
3. Set the COFF parameter to 40ms
4. Enable the breech sensor
5. Shoot the gun as quickly as you can and measure the ROF on a rate of
fire meter
6. Adjust the COFF parameter and repeat 5 until the ROF is 11.8bps*
(increasing COFF reduces ROF)
7. Check that CDELAY + CON + COFF is greater than 84ms and if not then
increase CON
8. Exit the Setup menu
9. Check the rate of fire on a league approved ROF meter.
*The rate of fire settings on Egos are accurate however not all rate of
fire meters will read the same. We recommend that guns be set on the
safe side of the legal limit. The difference between 11.8 and 12.0bps is
only 1 extra ball every 59 shots!
**If your software does not have the RAMP 3 option then it will be
necessary to upgrade your software to the latest version.
-------------------------------------------------------------------------
Cheers Cliff...
PSP
In order to comply with the new 2008 PSP rule regarding gun firing
modes, we recommend that Eclipse markers should be configured as follows -
Ego 7 / Ego 8
1. Enter the Setup menu
2. Select (PRESET) (LOAD) and choose the PSP option
3. Select (MAX ROF) and set the value to 13.0*
4. Select (OFF ROF) and set the value to 13.0* or less (recommend 12.0)
5. Select (PRESET) (SAVE) and choose the USER 1 option to save these
settings for future use.
6. Exit the Setup menu
7. Check the rate of fire on a league approved ROF meter.
Ego 5 / Ego 6
1. Enter the Setup menu
2. Select (MODE) and choose the RAMP 1 or PSP option
3. Select (ROF CAP) and set the value to 13.0*
4. Select (OFF ROF) and set the value to 13.0* or less (recommend 12.0)
5. Exit the Setup menu
6. Check the rate of fire on a league approved ROF meter.
Etek / Etek 2
1. Enter the Setup menu
2. Select Firing Mode (red) and set the value to 03.0 (Ramp 1)
3. Select Maximum ROF (green) and set the value to 13.0*
4. Select Maximum ROF with BBSS Disabled (blue) and set the value to
13.0 or less (recommend 12.0)
5. Exit the Setup menu
6. Check the rate of fire on a league approved ROF meter.
Planet Eclipse no longer provides software updates for the eBlade
platform, however the following may prove useful in setting these products
up to be compliant
E2 / Zero B
1. Fit fresh batteries to the loader that will be used and set the
loader speed as required
2. Enter the Setup menu
3. Select (MODE) and choose the RAMP 1 or PSP option
4. Set the COFF parameter to 40ms
5. Enable the breech sensor
6. Shoot the gun so that it ramps and measure the ROF on a rate of fire
meter
7. Adjust the COFF parameter and repeat 6 until the ROF is 13.0bps*
(increasing COFF reduces ROF)
8. Check that CDELAY + CON + COFF is greater than 77ms and if not then
increase CON
9. Exit the Setup menu
10. Check the rate of fire on a league approved ROF meter.
E1 (eBlade)
1. Fit fresh batteries to the loader that will be used and set the
loader speed as required
2. Enter the Setup menu
3. Set the COFF parameter to 40ms
4. Enable the breech sensor
5. Shoot the gun as quickly as you can and measure the ROF on a rate of
fire meter
6. Adjust the COFF parameter and repeat 5 until the ROF is 13.0bps*
(increasing COFF reduces ROF)
7. Check that CDELAY + CON + COFF is greater than 77ms and if not then
increase CON
8. Exit the Setup menu
9. Check the rate of fire on a league approved ROF meter.
*The rate of fire settings on Egos are accurate however not all rate of
fire meters will read the same. We recommend that guns be set on the
safe side of the legal limit. The difference between 13.0 and 13.33bps
is only 1 extra ball every 39 shots!
Millinnium
In order to comply with the new Millennium rule regarding gun firing
modes, Eclipse markers should be configured as follows -
Ego 7 / Ego 8
1. Enter the Setup menu
2. Select (PRESET) (LOAD) and choose the MILLEN option
3. Select (MAX ROF) and set the value to 11.8*
4. Select (OFF ROF) and set the value to 11.8*
5. Select (RAMP SET) (KICK IN) and set the value to 6.0
6. Select (RAMP SET) (SUSTAIN) and set the value to 6.0
7. Select (PRESET) (SAVE) and choose the USER 1 option to save these
settings for future use.
8. Exit the Setup menu
9. Check the rate of fire on a league approved ROF meter.
Ego 5 / Ego 6
1. Enter the Setup menu
2. Select (MODE) and choose the RAMP 3** option
3. Select (ROF CAP) and set the value to 11.8*
4. Select (OFF ROF) and set the value to 11.8*
5. Exit the Setup menu
6. Check the rate of fire on a league approved ROF meter.
Etek / Etek 2
1. Enter the Setup menu
2. Select Firing Mode (red) and set the value to 05.0 (Ramp 3)
3. Select Maximum ROF (green) and set the value to 11.8*
4. Select Maximum ROF with BBSS Disabled (blue) and set the value to
11.8*
5. Exit the Setup menu
6. Check the rate of fire on a league approved ROF meter.
Planet Eclipse no longer provides software updates for the eBlade
platform, however the following may prove useful in setting these products
up to be compliant
E2 / Zero B
1. Fit fresh batteries to the loader that will be used and set the
loader speed as required
2. Enter the Setup menu
3. Select (MODE) and choose the RAMP 3** option
4. Set the COFF parameter to 40ms
5. Enable the breech sensor
6. Shoot the gun so that it ramps and measure the ROF on a rate of fire
meter
7. Adjust the COFF parameter and repeat 6 until the ROF is 11.8bps*
(increasing COFF reduces ROF)
8. Check that CDELAY + CON + COFF is greater than 84ms and if not then
increase CON
9. Exit the Setup menu
10. Check the rate of fire on a league approved ROF meter.
E1 (eBlade)
1. Fit fresh batteries to the loader that will be used and set the
loader speed as required
2. Enter the Setup menu
3. Set the COFF parameter to 40ms
4. Enable the breech sensor
5. Shoot the gun as quickly as you can and measure the ROF on a rate of
fire meter
6. Adjust the COFF parameter and repeat 5 until the ROF is 11.8bps*
(increasing COFF reduces ROF)
7. Check that CDELAY + CON + COFF is greater than 84ms and if not then
increase CON
8. Exit the Setup menu
9. Check the rate of fire on a league approved ROF meter.
*The rate of fire settings on Egos are accurate however not all rate of
fire meters will read the same. We recommend that guns be set on the
safe side of the legal limit. The difference between 11.8 and 12.0bps is
only 1 extra ball every 59 shots!
**If your software does not have the RAMP 3 option then it will be
necessary to upgrade your software to the latest version.
-------------------------------------------------------------------------
Cheers Cliff...