out of date?

Tom Allen

TFP
Jul 4, 2003
8,196
123
148
Cardiff
probably not, but more details and a pic of the info will say for sure

bottle manufacturer ?
born date ?
max pressure ?
type of bottle ?
 

Scotty J M

UK Asylum Div 1 CPPS
Mar 10, 2008
598
1
0
Brackley
probably not, but more details and a pic of the info will say for sure

bottle manufacturer ?
born date ?
max pressure ?
type of bottle ?
nitro duck air
cant see where it says the born date :S
4500psi
fibre wrap
HP and LP . is got a adjustable reg
 

Tom Allen

TFP
Jul 4, 2003
8,196
123
148
Cardiff
it will have a born date, and will look like "2003/06" or something similar.

the bottle manufacturer would be something like Carleton, sci, luxfer.
 

Scotty J M

UK Asylum Div 1 CPPS
Mar 10, 2008
598
1
0
Brackley
HSE-AL-FW2 12-CL-02
Serial Number Filling Pressure Test Pressure
6151-88450 310BAR PH 517 BAR
water capacity: L1.1 Alum.Alloy: AA6061
empty weight:0.9kg Thread: .625-18UNF
Design life: 15 years Made: USA
________________________________________
DOT - E11194 4500PSI REE 15.cc
TC-SU 5303 310 BAR
6151-88450 M4927 12-CL-02
________________________________________
WARNING: Do not fill if cylinder has visual damage
unraveling or charring of composite fiber. For more
inofrmation, please visit www.cylindersafety.com

RESTEST EVERY 5 YEARS PER US DOT - E11194
RETEST EVERY 3 YEARS PER HSE-AL-FW2 & TC-SU 5303




thats whats on the bottle along with a yellow sticker with H-Pac service ltd
date of test 7/02/06
 

Tom Allen

TFP
Jul 4, 2003
8,196
123
148
Cardiff
HSE-AL-FW2 12-CL-02
Serial Number Filling Pressure Test Pressure
6151-88450 310BAR PH 517 BAR
water capacity: L1.1 Alum.Alloy: AA6061
empty weight:0.9kg Thread: .625-18UNF
Design life: 15 years Made: USA
________________________________________
DOT - E11194 4500PSI REE 15.cc
TC-SU 5303 310 BAR
6151-88450 M4927 12-CL-02
________________________________________
WARNING: Do not fill if cylinder has visual damage
unraveling or charring of composite fiber. For more
inofrmation, please visit www.cylindersafety.com

RESTEST EVERY 5 YEARS PER US DOT - E11194
RETEST EVERY 3 YEARS PER HSE-AL-FW2 & TC-SU 5303




thats whats on the bottle along with a yellow sticker with H-Pac service ltd
date of test 7/02/06
ok, it's a carleton bottle made in December 2002 "12-CL-02"
these bottles may have to be tested every 3 years rather than every 5 years for sci and luxfer, so that means it's probably out of test. You could check with hpac tomorrow.
 

Scotty J M

UK Asylum Div 1 CPPS
Mar 10, 2008
598
1
0
Brackley
ok, it's a carleton bottle made in December 2002 "12-CL-02"
these bottles may have to be tested every 3 years rather than every 5 years for sci and luxfer, so that means it's probably out of test. You could check with hpac tomorrow.
ok cheers :)

i thought i check because some people say its now 5 years because h-pac retested it :) but i will ring up h-pac :) cheers
 

Tom Allen

TFP
Jul 4, 2003
8,196
123
148
Cardiff
in 2003 the rules regarding testing changed and some manufacturers had the 3 year test period extended to 5 years, but it looks like Carleton didn't get this 5 year rule on their bottles.

The test period is not affected by the testing station, it's set by the governing body.
 

Rider

scottishwarriors.co.uk
RETEST EVERY 3 YEARS PER HSE-AL-FW2 & TC-SU 5303

thats whats on the bottle along with a yellow sticker with H-Pac service ltd
date of test 7/02/06
the Heath & Safety Executive guidelines on those category of Aluminium fibre wraps was 3 yearly - which would put you out of date (retest as per HPAC sticker would've been 7th Feb this year....)

however, some bottles can be tested to pi standard at retest putting them on the 5 year cycle, rather than the 3.

as tom says, check with HPAC to find out if this was the case for your bottle.